g. Damper locks together without bolts, screws, or. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. Specifier Select Option Dampers shall be equipped with factory installed damper. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. • Airfoil blade design for low pressure drop and reduced noise generation. Louver blades are . • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. AUTHORITY IN AIR CONTROL The (D)IBD20G meets the requirements for fire dampers established by: National Fire Protection Association NFPA Standards 90A and 101 ICC International Building Codes CSFM California State Fire Marshal Fire Damper Listing (#3225. The Ruskin Wireless Inspector™ includes the RFDI (Radio Frequency Damper Interface) located at each damper withCeiling Fire Dampers UL Classified Radiation Dampers for Wood Truss Construction The CFD7T is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586,. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM. ,Application The No. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowSun Control Sunshades. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. ft. Dampers above 18" (457) – 10 gage steel (3. • For proper operation, damper must be installed square and free from. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. Model ‘G’ curtain fire dampers are offset. The standard location permits the damper to be installed outside the plane of the wall or floor. angles together at corners of dampers. Opposed blade dampers must be operated from a power blade on the. g. 2. Built from. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL. PRESSURE DROP INFORMATION Performance curves based on AMCA Standard 500 using test setup apparatus figure 5. Minimum damper size for BD6 with SPC is 12" x 12" (305 x 305). 1/4” cfm at 4” w. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowIBD2G, IBD2SSG (Static) and DIBD2G, DIBD2SSG (Dynamic) curtain type fire dampers for grille installation may be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. (Consult Ruskin for detailed CSI MasterFormat Specification. Learn more about the features and. • Airfoil High Performance Dampers • Triple-V Standard Performance Dampers • Ruskin Exclusive True Round Dampers • Ruskin Fast Mounting Angles • Complete Corridor. Testing has proved that the CD40x2 insulated more efficiently than conventionally insulated blades. per sq. See “Combination Fire Smoke Damper Multiple Section Detail” spec Ruskin February 222 Page 1 FDR25SS Stainless Steel True Round Fire Damper 1 1/2 Hour UL555 Ratings for use in Dynamic & Static Systems Ruskin FDR25SS is a stainless steel true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. Damper bearings shall be of UHMW and mechanically fastened by stainless steel set collars located out of the airstream. Conservative ratings are presented intentionally in an effort to avoid misapplication. (1 kPa). the damper/sleeve. Higher velocities are not recommended for outside air openings, due to water penetration concerns. Maximum rating of 4,000 fpm and 8" w. • Kansas City, MO 64030 • (816) 761-7476 vFBD35 IRIS BALANCINg DAMpER Ruskin IRIS Balancing Damper model VFBD35 is an excellent solu -For other damper sizes refer to Air Performance Data For All Smoke Dampers spec sheet. com W: Genset dampers are designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment or surrounding space. and a maximum of 3 CFM sq. It also features: Frame corners that are internally braced to reduce racking. Ruskin Literature. static pressure. The TS150 must be installed at the factory and cannot be added in the field. Air Measuring Station with Integral Damper: 15" 300-5000: Transducer (LCD Display Optional) Optional: 3%: W 6" H 6" W 60" H 72" Velocity Pressure:. Ruskin September 2021 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50GS is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. Damper frames Dampers shall be constructed with premium vinyl ester resins suitable for. Ruskin CD60DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Designed to protect life and property, Ruskin® manufactures a complete line of UL classified dampers. The PVC12 damper is a corrosion-resistant and low-maintenance device that can regulate air flow in ducts or pipes. The majority of designs are rated at 2 or 3 hours. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. Actuators enable a damper to operate with controlled positioning throughout the stroke of the damper. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. They also offer a new coupler option that joins two damper sections without a jackshaft allowing an actuator to be mounted on side of frame to provide a narrow profile when space is limited. The FSDR25C is a round tunnel corridor fire/smoke damper with UL555 Classification as a 1 ½ hour rated fire damper and a Leakage Class I UL555S Smoke Damper. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design. 2. Ruskin May 2020 Page 1 Models CFD(R)2, CFD(R)3, CFD(R)3. Ruskin model CD60 offers HVAC design engineers an ultra-low leak high performance damper which provides: • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Insulating Control Dampers. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. g. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. CFD7 - 2"x10" or 2"x12" Joist Assemblies (Ref. . g. FSD36 126"x 96"or 72"x 122" 4"w. Damper shall be equivalent to Ruskin model ARD25. 247. Automatic Balancing Dampers. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. Multi-section dampers typically use jackshafts to link sections together. It features: Extruded aluminum construction. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Ruskin Literature. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM 3. Louver Paint Finishes - Color Guide. 2. The calibrated locking hand quadrant is coordinated with specific aperture. Sun Control Sunshades. The Manufacturers we represent are industry leaders such as Loren Cook (fans), Ruskin (dampers, louvers) and Krueger (air distribution products). All (D)IBD Curtain Type Fire Dampers Excluding IBDT Series model – FLIB fd fuse link assembly 1. Hexagonal axles that ensure a positive lock with blades. The switch package shall include two position indication switches linked directly to the damper blade to provide full open and full closed damper. Ruskin ® 00 Dr. Ruskin's Insulating Control Dampers are perfect for performing this task. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Enter the Pressure Drop Chart at the determined area factor. LEADS; TDP05K Placement Tool; Windload Calculator; Resources. 7447 Toll Free: 800. FILES (0) Share this page: Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Ruskin Green Products. 500. Axles that positively lock to blades without screws or welds. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). (2 kPa). Excellent weather protection when installed in. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. Select the damper size. UL555S rating up to 350°F (177°C). Combination louvers can incorporate both drainable and non-drainable blades which are selected based on the structure. angles together at corners of dampers. II. When joining multiple damper assemblies or fastening the damper to the sleeve, dampers shall be fastened with 1/4-20 (M6) bolts, number 10 (M5) screws, or 1/2" (13) long welds stag-gered intermittently on both sides. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (3) steel rivets or 1/2" (13) long welds. Noise Control. Refer to the UL approved installation instructions for specific requirements. Fire dampers are UL555 tested and labeled devices installed in ducts and air transfer openings or air distribution systems, designed to close upon the detection of heat. Certain actuators in Table 1 are UL Recognized Components under. Higher velocities are not recommended for outside air openings, due to water penetration concerns. ft. Enter the Pressure Drop Chart at the determined area factorRuskin April 2021 Page 3 DAMPER SLEEVE DIMENSIONAL DATA The drawings show the position of the damper mounted in the factory sleeve. pivot pins. upstream of the damper. Use "Mount With Arrow Up" label as a guide for proper damper orientation. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. g. Actuators and accessories are factory mounted on the right side when viewed from the actuator side of the wall or floor. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. The FSDR60 is the ideal choice when round duct is used on a project. The bubble tight isolation damper shall be manufactured in an ISO9001 certified factory. Dampers shall be in all respects equivalent to Ruskin Model CD40. Access Doors. Linkage is concealed in the frame out of the airstream for low maintenance and reduced. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. The FDR25SS is rated for maximum velocity of 2,000 fpm and 4” w. , which meets the International Energy Conservation Code (IECC) requirements. Noise Control. , with order). consider an airfoil blade damper, such as Ruskin model CD60. lbs. All data has been cor- Dampers 18" (457) and under – 12 gage steel (2. The DIBD2/OW can be installed on either side of the wall or top or bottom side of the floor. 350° Vertical or Horizontal SIze StAtIC PReSSURe teMPeRAtURe INStALLAtIoN ACtUAtoR ReqUIReMeNtS * UL555S requires that all. FILES (0) Share this page: Ruskin's Automatic Balancing Dampers provide a reliable way to maintain constant airflow volume and occupant comfort in high-rise buildings. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . • Fire smoke dampers larger than single section may require multiple actuators. The CD60GS also provides AMCA class 1A leakage rating of 3cfm/ft2 at 1”. Various relief air control settings are created by simple. Dampers shall be Ruskin model FSDR25. Designed for isolation and containment of the airstream, Ruskin Bubbletight industrial dampers for round and rectangular air paths will meet or exceed bubbletight leakage requirements in conformance with AMCA Standard 500-D Section 8. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. From dampers and louvers, to air measuring systems and ERVs, Ruskin ® is recognized for consistent innovation, engineering excellence and precision manufacturing. 3. These same finishes provide extended weathering resistance similar to adjacent building surfaces. Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies in. 2. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. Dampers shall be in all respects equivalent to Ruskin Model CD40. UL qualifies the damper and its actuator for performance after 30 minute exposure to elevated temperatures. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. 248 Kpa) tested per AMCA 500. The damper and sleeve assembly can be installed completely from one side of the wall and does not require mounting angles on the backside. Each fire damper shall be labeled for use in dynamic systems. After 15 minutes, the damper is closed and reopened. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. The maximum opening. Stainless Steel Construction See model (D)IBD2SS. static pressure. The ELBD375E Automatic Exhaust Dual Combination aluminum louver combines a drainable blade louver and an exhaust backdraft damper in a nominal 6” frame depth. The CD51 can be utilized in systems calling for less than 10 cfm/sq. The AiQ-TD-50 offers accurate airflow measurement and control through electronicthermal dispersion technology utilized in Ruskin model TDP05K Airflow & Temperature Measuring probes(s) with the inclusion of Ruskin model CD50 control damper factory configured as one compact assembly. This damper has insulated extruded aluminum blades with a thermal break and twin blade edge seals that ensure low leakage and reliable performance. Consult Ruskin or your Ruskin representative when damper is to be. Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. Equipped with linkage out of the airstream. 8955DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Greaves Rd. Relief doors open automatically to prevent ductwork from imploding or exploding due to differential pressure. Ceiling fire dampers, also known as "Radiation" dampers, are designed and tested to limit the radiant heat transfer through an air inlet/outlet opening in the ceiling membrane of a fire resistance rated floor/ceiling or. These models combine the strength of stainless steel and the protection of anodized aluminum to combat salt water elements. Maximum 8" static pressure UL approval for dual directional airflow Failsafe design, which enables the damper to automatically assume the desired. The CDRS15 is a true round commercial control damper that installs easily in round spiral ductwork. Caution: Volume Adjust hangs below a rectangular damper 1 1/8”® Furnish and install at locations shown on plans or in accordance with schedules, bubble tight isolation dampers meeting the following specifications. It features: Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Blade Insulation CSFM 3225-0245:0101. The TDPOSK is a highly accurate thermal dispersion airflow and temperature measuring probe. The FD35/OW, FD35SS/OW and FD60/OW static fire dampers are for use in static (fans off) systems only. Industrial Multi-Blade Control Damper. g. It can be equipped with the industry's shortest sleeve and is ideally suited for shaft wall applications. FSD35 FSD36 FSD60 CDO25 CDO25 CD35 CD36 CD50 CD60. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. Reinforcing plates are not required for assemblies consist-ing of two dampers attached end-to-end or three dampers attached side-to-side as depicted in figure 3. All data has been. ©Ruskin 2000 3900 Dr. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. Installation Instructions FSD60FA, FSD36FA, and FSD60FA-M Front Access Combination Fire & Smoke Damper 11/2 HOUR UL555 & UL555S CLASS I OR CLASS II CLASSIFIED RATING Author: Ruskin - Dampers Louvers (816) 761-7476 Subject: Models FSD60FA, FSD60FA-M, and FSD36FA combination fire/ smoke dampers are. Ruskin manufactures a complete line of louver models available for both standard and special needs, such as high-volume airflow, wind driven rain, special architectural shapes, sight proof. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . Louvers & Architectural. Ruskin’s adjustable louvers and louver/damper combinations allow our customers to enjoy the benefit of architectural styling with air control and shut off. Actuator can be field converted to power open and spring or "fail" closed. angles together at corners of dampers. • Operation Test The damper/actuator assembly is exposed to heated (250ºF or 350ºF) airflow (minimum 2,400 fpm and 4. 3. 5hr Dynamic Fire Dampers » 3hr Dynamic Fire Dampers » 1. 3 m/s) and 8” w. Counter Balanced Backdraft Damper. MINIMUM SIZE Vertical Installation – 4"w x 4"h (102 x 102). a. (Consult for electronic version of this “Quick” spec as well as for complete 3-part CSI MasterFormat Specifications)Ruskin model ABD offers HVAC design engineers an automatic balancing damper which provides: • Energy savings to building owner • Constant maintained airflow volume • Good indoor air quality • Anti-microbial agent prohibiting bacteria or mold growth • Easy installation; requires no tool for adjustment. Corrosion. Industrial FAQs. • Ruskin frame-mounted actuator bracket to simplify field installation of most actuators (specify actuator and action, i. 8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. a. damper section width as indicated. Supported by US Headquarters, Ruskin is the world largest and innovative air control solutions manufacturer, we combine financial stability with pioneering. M. back pressure depending on damper size. Ruskin provides perfect control Fire Smoke Dampers. Ruskin's complete line of zone control products was developed to meet an increasing demand for zone specific products combined with individual controls. Ruskin CFD(R)2 and CFD(R)3 are UL Classified to provide protection to HVACRectangular Steel V-Groove. GENERAL INSTALLATION NOTES 1. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40,. For proper operation, damper must be installed square and free from racking. the following control damper models: CD50 CD504 CD40 CD403 CD51 T-Flange frame is available at additional cost for the following Ruskin commercial control damper models: CD60 CD36 CD356 IL35 CD35 CD355 MINIMUM SIZE Models CD50, CD504, CD60, CD356 and CD355, 6" x 4" (152 x 102). lbs. It is also: Flange mounted. The DTS gives maintenance personnel the ability to “cycle test” the fire/smoke damper by pushing and holding the button until the damper has cycled. The webpage provides the specifications and features of the Ruskin® CD80AF1 and CD80AF2 industrial control dampers, which are designed for heavy duty applications and high temperature environments. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. A. 3 m/s) and 8” w. Damper Width “A” Dimension in inches (mm)Round Control Damper Class 1A Leakage The CDRS25 “true round” control damper is designed for low to medium pressure and. It locks together without bolts, screws, or rivets that could shake loose. The operable blades are opened and closed manually, or with the use of an actuator. 350° Vertical FSD36 144"x 96" 4"w. Dampers shall be in all respects equivalent to Ruskin Model CD35. 25" w. Ruskin model CD50 offers HVAC design engineers an ultra-low leak high performance damper which provides; • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance. It: Is standard on all fire/smoke dampers ordered with pneumatic actuators. 7476 Fax: 816. g. Maximum velocity of 4,000 fpm. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. FILES (0) Share this page: Catalog. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Ruskin provides perfect control Fire Smoke Dampers. Greaves Rd. com. The airfoil blades are designed for HVAC systems with velocity and pressures up to 4,000 fpm and 8" w. Ruskin Literature. g. Noise Control. Actuators & Damper Accessories Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. com. CFD7T - 2"x4" Truss Assemblies (Ref. Ruskin Company certifies that the SD50 shown hereon is licensed to bear the AMCA Seal. Higher temperature ratings available consult Ruskin. Ruskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!March 23, 2022. The damper frames are made of galvanized steel in a channel frame construction, offering an equivalent 13-gauge metal strength. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Carbon steel construction. 765. Autodesk®Revit® is Building Information Modeling (BIM) at its best. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Ruskin® Labor Saversfor fire and fire/smoke dampers include factory sleeves, PFMA mounting angles, and tagging by floor or by area. Every damper is built with performance in mind and tested per AMCA standards. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. The CD80AF2 Industrial Control damper has an 8" frame. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 ® Nominal Diameter, Inches Total CFM. Mounting Angle Fastener Spacingon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. added to the damper at fabrication. Dampers shall be in all respects equivalent to Ruskin model IL35. Higher velocities are not recommended for outside air openings, due to water penetration concerns. 3. Available with factory furnished sleeves. What is an EFL device? The Ruskin electronic "resettable" fuse line (EFL) is a UL Classified heat response device for use in conjunction with Ruskin fire/smoke dampers. com . 5 hr. a. Galvanized Steel Airfoil Blades. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade Louver and Architectural. 24VAC modulating actuators (spring return or fail-in-place) can. Stops the leakage of smoke in static and dynamic smoke systems. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. 5. The damper is rated for Ruskin CD50DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Ruskin. Axles shall be square or hexagonal positively locked into the damper blade. Actuators and Damper Accessories. Ruskin® offers a comprehensive guide to its commercial dampers, including product features, specifications, installation instructions, and 3D Revit® files. Ruskin Control Dampers and Backdraft Dampers Get the air where you want it — when you want it! 3 CD60 Ultra Low Leakage Damper The CD60 damper is a “true” airfoil blade damper designed for medium to high velocity and. When equipped with blade seals, provides positive shut-off. Torque applied holding damper closed at 10 in. Easy installation. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. The CD60CE is designed for coastal regions and other corrosive environments such as salt-water regions. 075 lb/cu ft air. The Damper part prices in this catalog do include freight within the contiguous 48 states. and greater Carbon steel construction Butterfly bladeThe CFD7T-ST-BT is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548 and H502. 5. • Fire smoke dampers larger than single section may require multiple actuators. 0) sleeve. Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. F. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476 Document Title O & M for Commercial Control Dampers Limited Warranty Document LINKS TO IMPORTANT. Every damper is built with performance in mind and tested per AMCA standards. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. Life Safety Products; Louver and Architectural; Louver Paint Finishes - Color Guide; Diffusers; Energy Recovery Ventilators; Commercial Control DampersRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD60FA is a combination fire/smoke damper that allows through the grille access to the damper, actuator and heat actuated device. Keywords: Ruskin, Commercial, backdraft, damper S3G, Data, Submittal, galvanized, steel Created Date: 1/5/2017 12:58:19 PMRUSKIN finishes enhance product appearance to blend with other colors selected. to. The new DC "data center" models are high-performing airfoil blade type, and offer the lowest AMCA Class 1A leakage rating for energy savings. The CD60CE in 316 stainless steel construction offers superior corrosion resistance and. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. 15/1, Moo 9, Kabinburi Korat Road, Prachinburi 25110 Thailand. the application of firestopping caulk in the annular space surrounding a fire or fire/smoke damper <b>is not. Dampers may tolerate higher pressures and velocities than those listed here. Counterbalance weights that can be set to relieve air pressure differentials less than . Commercial dampers provide low-pressure openings with excellent pressure-drop performance. STATIC PRESSURE IN IN. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. Use the details shown on pages 2 and 3 to determine how Ruskin multiple blade dampers with standard construction and sizes up to 240" wide by 144" high will be assembled and manufactured. Complete with 24V modulating actuator and field wired wall mounted, the thermostat gives individual control to office spaces with single or multiple branch ducting. Learn more about the FSD60 and its installation instructions from this document. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. It features: Low leakage. For the name and address of your Ruskin Representative, call (816) 761-7476, or visit our web site at Ruskin can engineer and install pneumatic, electric or manual type actuation to best meet your specifications. Expansion Clearance – The opening in the wall or floor must be a minimum of 1/8" per foot (3 per 305) larger than the overall damper/sleeve assembly. Fire/smoke dampers must be installed so the leading edge of the closed blades are within the barrier it is intended to protect (unless specifically designed for out of wall or floor applications). 2. Issue ‘E’ Fuse Link 4. 56 psi and 38. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. We service the Mechanical Contractor and Mechanical Engineering community in Southern California. 2. (0. In addition, the DC models have. Greaves Road Grandview MO 64030 Phone: 816-761-7476 ruskin@ruskin. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. UL approval for dual directional air flow. The unit has encapsulated iris segmented blades and integral air pressure taps for great flow control and validation. Dampers may tolerate higher pressures and velocities than those listed here. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. Fasteners and Multiple Section Assembly When joining multiple damper assemblies or fastening the damperThe S2SS Backdraft damper has a 2" frame. 3. g. Every damper is built with performance in mind and tested per AMCA standards in Ruskin's Laboratory. g. TION 1. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. Standard features vary by model to. 5 inches (89) Furnish and install, at locations shown on plans or as in accordance with. PRESSURE DROP INFORMATION Performance curves based on AMCA Standard 500 using test setup apparatus figure 5. The damper is rated for maximum velocity of 2,000 fpm (10. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations.